Index index by Group index by Distribution index by Vendor index by creation date index by Name Mirrors Help Search

ddcutil-service-1.0.11-lp160.1.1 RPM for s390x

From OpenSuSE Leap 16.0 for s390x

Name: ddcutil-service Distribution: openSUSE Leap 16.0
Version: 1.0.11 Vendor: openSUSE
Release: lp160.1.1 Build date: Thu Aug 22 03:18:47 2024
Group: System/GUI/Other Build host: reproducible
Size: 131358 Source RPM: ddcutil-service-1.0.11-lp160.1.1.src.rpm
Packager: https://bugs.opensuse.org
Url: https://github.com/digitaltrails/ddcutil-service
Summary: D-Bus service for libddcutil VESA DDC Monitor Virtual Control Panel
ddcutil-service is D-Bus service wrapper for libddcutil which
implements the VESA DDC Monitor Control Command Set. In general,
most things that can be controlled using a monitor's on-screen
display can be controlled by this service.

Provides

Requires

License

GPL-2.0-or-later

Changelog

* Thu Aug 22 2024 Michael Hamilton <michael@actrix.gen.nz>
  - 1.0.11
    - Alter the detect-function for ddcutil 2.5.1 (generates more logging/warning info).
    - Add a DETECT_ALL option to control whether disabled/powered-off VDU's are to be included in the results from detect.
    - Reduce the number of messages generated when polling for hotplug events.
    - Fixes to API documentation.
* Thu Jun 13 2024 Michael Hamilton <michael@actrix.gen.nz>
  - 1.0.9
    - Fixed a GetCapabilitiesMetadata bug that caused some VCP features to lack metadata values.
    - Fixed the return of feature-name and feature-description from GetVcpMetadata.
    - Fixed potential hot-plug/DPMS polling memory leaks and simplified event locking.
    - Recoded hot-plug/DPMS polling to avoid a potential libddcutil assertion failure.
    - Fixed code/doc typos, improved code readability/structure, reduced IDE warnings.
    - Updated documentation to caution against excessive updates when coding loops, as this may impact VDU NVRAM lifespan.
    - Updated documentation to caution against experimenting with non-standard features, as it may risk damage to the VDU.
* Thu May 16 2024 Michael Hamilton <michael@actrix.gen.nz>
  - 1.0.7
    - Slightly improved setvcp diagnostics.
    - Fix methods failing with return code DDCRC_OTHER (-3022) when only some i2c devices are accessible.
* Mon Apr 29 2024 Michael Hamilton <michael@actrix.gen.nz>
  - 1.0.6
    - Add SetVcp/SetVcpWithContext NO_VERIFY (no retry) flag option.
    - Match the behaviour of the ddcutil command, default to verify-and-retry for all set-vcp method calls.
    - Default to verify-and-retry for all libddcutil versions.
    - Replace the stateful DdcutilVerifySetVcp property with the stateless NO_VERIFY flag.
    - Fix the ServiceFlagOptions property so that it lists all flag options.
    - Check the status returned by libddcutil ddca_init() and exit on error to prevent any inconsistent behaviour.
    - Cleanup the --prefer-polling and --prefer-drm options to make them consistent with each other.
* Fri Apr 12 2024 Michael Hamilton <michael@actrix.gen.nz>
  - 1.0.4
    - Provide an API flag RETURN_RAW_VALUES which disables GetVcp high-byte masking of Simple Non-Continuous features.
    - Provide the --return-raw-values command line option for the same purpose.
* Mon Apr 01 2024 Michael Hamilton <michael@actrix.gen.nz>
  - 1.0.3
    - Reduce unnecessary logging.
    - Improve the description of the service's signals in ddcutil-service.1.
    - Correct the typo in option name --perfer-drm (it was mistakenly called --prefer-dma).
    - For simple VCP-features, only return the low-byte, for some VDUs the high-byte might contain junk.
* Thu Feb 29 2024 Michael Hamilton <michael@actrix.gen.nz>
  - Version 1.0.2
    - Added VcpValueChanged D-Bus signal which triggers if the SetVcp method succeeds. This is to allow
      multiple clients to be aware of changes made by each.
    - Added SetVcpWithContext which accepts a client-context to be returned with the VcpValueChanged signal.
    - ServiceEmitSignals renamed to ServiceEmitConnectivitySignals to avoid confusion.
    - Command line option --emit-signals renamed to --emit-connectivity-signals for the same reason.
    - Fix ServiceEmitSignals property assignment so that it correctly toggles hotplug signals.
    - Fix hotplug polling so that it remains an option no matter what version of libddcutil is in use.
  - Version 1.0.1
    - Use gcc with -Wformat-security for safety and to match Arch and Ubuntu defaults.
    - Calling ddca_init() before verify_i2c() to fix runtime error for libddcutil >= 2.1.
* Thu Jan 18 2024 Michael Hamilton <michael@actrix.gen.nz>
  - Version 1.0.0
    * Added an optional D-Bus interface to ddcutil for up 10x faster response times.

Files

/usr/bin/ddcutil-service
/usr/lib/modules-load.d
/usr/lib/modules-load.d/ddcutil-service.conf
/usr/share/dbus-1
/usr/share/dbus-1/services
/usr/share/dbus-1/services/com.ddcutil.DdcutilService.service
/usr/share/ddcutil-service
/usr/share/ddcutil-service/examples
/usr/share/ddcutil-service/examples/busctl.bash
/usr/share/ddcutil-service/examples/dbus-enable-info-logging.bash
/usr/share/ddcutil-service/examples/dbus-enable-signals.bash
/usr/share/ddcutil-service/examples/dbus-send-detect.bash
/usr/share/ddcutil-service/examples/dbus-send-introspect.bash
/usr/share/ddcutil-service/examples/dbus-send-query-brightness.bash
/usr/share/ddcutil-service/examples/dbus-set-polling-interval.bash
/usr/share/ddcutil-service/examples/ddcutil-dasbus-client.py
/usr/share/ddcutil-service/examples/ddcutil-dasbus-signal-receiver.py
/usr/share/ddcutil-service/examples/ddcutil-qtdbus-client.py
/usr/share/ddcutil-service/examples/ddcutil-qtdbus-signal-receiver.py
/usr/share/licenses/ddcutil-service
/usr/share/licenses/ddcutil-service/COPYING
/usr/share/man/man1/ddcutil-service.1.gz
/usr/share/man/man7/ddcutil-service.7.gz


Generated by rpm2html 1.8.1

Fabrice Bellet, Tue Nov 12 00:24:29 2024