Index | index by Group | index by Distribution | index by Vendor | index by creation date | index by Name | Mirrors | Help | Search |
Name: apcupsd | Distribution: openSUSE Leap 15.2 |
Version: 3.14.14 | Vendor: openSUSE |
Release: lp152.6.3 | Build date: Thu Feb 6 10:43:25 2020 |
Group: Hardware/UPS | Build host: obs-arm-6 |
Size: 1252481 | Source RPM: apcupsd-3.14.14-lp152.6.3.src.rpm |
Packager: https://bugs.opensuse.org | |
Url: http://www.apcupsd.com/ | |
Summary: APC UPS Daemon (Powerful Daemon for APC UPSs) |
Controls and monitors the status of an APC UPS under Linux. Allows your computer or server to run for a specified length of time on UPS power then executes a controlled shutdown in the case of an extended power failure. Find APC on the Internet at http://www.apc.com/. APC also made their PowerChute plus available for download at http://www.apc.com/tools/download/.
GPL-2.0-only
* Thu Mar 15 2018 tchvatal@suse.com - Drop support for < sle12, also removes patch: * apcupsd-pm-utils.patch - Drop intitscript - Format with spec-cleaner - Use license macros instead of %doc macros * Mon Dec 11 2017 crrodriguez@opensuse.org - BuildRequire pkgconfig(x11) not xorg-x11-devel * Thu Nov 23 2017 rbrown@suse.com - Replace references to /var/adm/fillup-templates with new %_fillupdir macro (boo#1069468) * Thu Aug 31 2017 dimstar@opensuse.org - Pass --with-distname=, based on the values of ID_LIKE from /etc/os-release to configure. Since the removal of /etc/SuSE-release, the build system is no longer able to identify us building on a SUSE system. Let's help it. * Thu Dec 08 2016 manfred99@gmx.ch - update apcupsd-httpd.conf to work with apache2 >= 2.4. Entries are commented out, so this file acts as example only. bsc#950950 * Tue May 31 2016 manfred99@gmx.ch - Update to apcupsd version 3.14.14 * win32: Fix missing DLLs when installing only apctray * Fixes for socket error handling. Resolves apcaccess crash when connection fails as well as several other theoretical issues. * MODBUS/USB error handling (COMMLOST) improvements for faulty USB links * Fix hiddev binding when usbfs is mounted on /dev/bus/usb instead of /proc/bus/usb. This is necessary for switching between MODBUS/USB and USB/HID on Linux. * Update GPLv2 text and FSF address to match current versions from FSF. * Various fixes for potential issues suggested by Coverity Scan * MacOS X port support for El Capitan System Integrity Protection (SIP) aka "rootless" * Fix shutdown failure on Windows when UPSNAME includes spaces * Fix building bsd-usb driver (This was broken when modbus-usb support was added.) * Add status display for output current as well as apparent power - fix firewall rule installation in spec file - drop BuildRequires: net-snmp-devel, net-snmp was dropped in favour of snmplite - drop installation of own automake files for ppc64, not needed any more - Removed patches, fixed in upstream: * apcupsd-3.14.6-undef-MIB-for-new-net-snmp.diff * fix-fsf-adress.patch * apcupsd-3.14.1-cloexec.patch * apcupsd-gpp.patch - Removed patch, not needed as it builds on all supported arches, and not linking against libstdc++ is done on purpose: * apcupsd-3.14.8-cxxld.patch * Mon Jul 13 2015 tchvatal@suse.com - Ensure locfile is properly set bnc#929444 * Sat Apr 18 2015 matwey.kornilov@gmail.com - Move *.cgi scripts to apcupsd-cgi package (fix boo#925886) * Thu Apr 02 2015 tchvatal@suse.com - Version bump to 3.14.13: * apcaccess and apcupsd status format updates to ease parsing by scripts * UPS name is included in subject line of emails in default scripts * Default event scripts pull SYSADMIN and APCUPSD_MAIL definitions from a common config file so they can easily be configured in one place * MODBUS USB support Previous releases supported MODBUS serial (RS232). This release adds support for MODBUS over USB. This protocol is preferable to the normal USB HID driver because it offers access to more UPS data readouts and controls. The only configuration file change needed versus MODBUS serial is to change UPSCABLE to usb and use an empty DEVICE setting. See the MODBUS section of the apcupsd manual for more details. * Support for Apple Notification Center on Mac OS X (replaces Growl) * Apple install packages and binaries are signed with an Apple Developer key for compatibility with Gate Keeper * Windows USB driver has been updated with additional USB identifiers to support future APC products. * Fix issue with certain Back-UPS USB models repeatedly cycling power on/off after killpower is issued * Fix display of battery level during MODBUS calibration * Fix apctest EEPROM setting on various models * Close and reopen serial port during extended COMMLOST in apcsmart driver (helps recover connection when USB serial port dongles are reconnected) * Avoid probing non-APC USB devices as it can cause lockups * Fix issue with service failing to start on Windows during boot with USB UPS * Fix bogus lock file error when config file error forces early termination * Fix MODBUS NOMOUTV reading for voltages other than 120VAC * Fix LOADPCT (CI_LOAD) on MODBUS driver * Fix issue with net driver not reporting MODEL value * Fix several potential issues identified by Coverity static analysis * Numerous other fixes and improvements all over the code, many of them submitted by users...Thank you! - Refreshed patches: * apcupsd-3.14.1-cloexec.patch * apcupsd-3.14.8-cxxld.patch * apcupsd-gpp.patch - Removed patch: * apcupsd-3.14.10-nodbg.patch * Thu Apr 02 2015 tchvatal@suse.com - Cleanup with spec-cleaner - Remove patch that is never applied today: * apcupsd-powersave.patch * Tue Dec 02 2014 sbrabec@suse.cz - Fix removal of HALT_POWERDOWN_INSERT (bsc#907702). * Sun Nov 16 2014 matwey.kornilov@gmail.com - Add patch apcupsd-3.14.10-nodbg.patch: reduce amount of debug messages (redhat #1053324) * Sun Nov 16 2014 matwey.kornilov@gmail.com - fix HIBERNATE variable initialization in apccontrol script
/etc/apcupsd /etc/apcupsd/apccontrol /etc/apcupsd/apcupsd.conf /etc/apcupsd/changeme /etc/apcupsd/commfailure /etc/apcupsd/commok /etc/apcupsd/offbattery /etc/apcupsd/onbattery /etc/logrotate.d/apcupsd /etc/sysconfig/SuSEfirewall2.d/services/apcupsd /usr/lib/systemd/system-shutdown/apcupsd_shutdown /usr/lib/systemd/system-sleep/apcupsd.sh /usr/lib/systemd/system/apcupsd.service /usr/sbin/apcaccess /usr/sbin/apctest /usr/sbin/apcupsd /usr/sbin/rcapcupsd /usr/sbin/smtp /usr/share/doc/packages/apcupsd /usr/share/doc/packages/apcupsd/ChangeLog /usr/share/doc/packages/apcupsd/README.SUSE /usr/share/doc/packages/apcupsd/ReleaseNotes /usr/share/doc/packages/apcupsd/examples /usr/share/doc/packages/apcupsd/examples/Makefile /usr/share/doc/packages/apcupsd/examples/SmartUPS1400.snmp /usr/share/doc/packages/apcupsd/examples/client.c /usr/share/doc/packages/apcupsd/examples/gui /usr/share/doc/packages/apcupsd/examples/gui/about.tcl /usr/share/doc/packages/apcupsd/examples/gui/apcupsd.tcl /usr/share/doc/packages/apcupsd/examples/gui/dialog.tcl /usr/share/doc/packages/apcupsd/examples/gui/events.tcl /usr/share/doc/packages/apcupsd/examples/gui/mainwindow.tcl /usr/share/doc/packages/apcupsd/examples/gui/pkgIndex.tcl /usr/share/doc/packages/apcupsd/examples/gui/splash.tcl /usr/share/doc/packages/apcupsd/examples/gui/status.tcl /usr/share/doc/packages/apcupsd/examples/hid-set.c /usr/share/doc/packages/apcupsd/examples/hid-ups.c /usr/share/doc/packages/apcupsd/examples/hiddev.h /usr/share/doc/packages/apcupsd/examples/index.php /usr/share/doc/packages/apcupsd/examples/libusb.h /usr/share/doc/packages/apcupsd/examples/make-hiddev /usr/share/doc/packages/apcupsd/examples/megaclient.c /usr/share/doc/packages/apcupsd/examples/nagios_plugin_check_apcupsd.c /usr/share/doc/packages/apcupsd/examples/newslave.c /usr/share/doc/packages/apcupsd/examples/offbattery.cpufreq /usr/share/doc/packages/apcupsd/examples/onbattery.cpufreq /usr/share/doc/packages/apcupsd/examples/php-monitor.txt /usr/share/doc/packages/apcupsd/examples/rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-350-USB.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-350ES.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-500-USB.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-500ES.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-BR-800.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-CS-650.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-ES-550.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Back-UPS-XS-1300-LCD.rpt /usr/share/doc/packages/apcupsd/examples/rpt/BackUPS.rpt /usr/share/doc/packages/apcupsd/examples/rpt/Smart-UPS-1500.rpt /usr/share/doc/packages/apcupsd/examples/rpt/SmartUPS-USB.rpt /usr/share/doc/packages/apcupsd/examples/rpt/SmartUPS.rpt /usr/share/doc/packages/apcupsd/examples/rpt/hid-ups.rpt /usr/share/doc/packages/apcupsd/examples/safe.apccontrol /usr/share/doc/packages/apcupsd/examples/smartsim.c /usr/share/doc/packages/apcupsd/examples/snoopdecode.c /usr/share/doc/packages/apcupsd/examples/status /usr/share/doc/packages/apcupsd/examples/status/Back-UPS-BX-1500.status /usr/share/doc/packages/apcupsd/examples/status/Back-UPS-Pro-1000.status /usr/share/doc/packages/apcupsd/examples/status/BackUPS-USB.status /usr/share/doc/packages/apcupsd/examples/status/JapaneseUPS.status /usr/share/doc/packages/apcupsd/examples/status/PowerStack450.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS-vs-650.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS1000.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS1400.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS3000.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS5000.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS600.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS700-2.status /usr/share/doc/packages/apcupsd/examples/status/SmartUPS700.status /usr/share/doc/packages/apcupsd/examples/status/newbackupspro1.status /usr/share/doc/packages/apcupsd/examples/status/newbackupspro2.status /usr/share/doc/packages/apcupsd/examples/upsapm.c /usr/share/doc/packages/apcupsd/examples/usb_hid_usages /usr/share/doc/packages/apcupsd/examples/usbsnoop.txt /usr/share/fillup-templates/sysconfig.apcupsd /usr/share/licenses/apcupsd /usr/share/licenses/apcupsd/COPYING /usr/share/man/man5/apcupsd.conf.5.gz /usr/share/man/man8/apcaccess.8.gz /usr/share/man/man8/apccontrol.8.gz /usr/share/man/man8/apctest.8.gz /usr/share/man/man8/apcupsd.8.gz
Generated by rpm2html 1.8.1
Fabrice Bellet, Tue Jul 9 12:19:47 2024